contact
 
Name
Email
Tel
Message
 
 
contact

IC Series Complete Premise Water Filters

Bacfree® IC Series Filters are developed and designed as a cost effective, efficient and reliable way of providing purified water for household, industrial and commercial applications. Ranging in size from 14cm (5.5”) to 300cm (118”) in diameter and with flow rates up to 250,000 litres (55,555 Gallons) in a single system arrangement, IC Series filters will meet your varying water filtration needs and ensure the highest quality, ease of operation and maintenance. The filters can be custom designed and pre-engineered to meet any of the specific application requirements.

  • Simple, reliable design for maximum performance and efficiency
  • SUS304 food grade non-toxic stainless steel construction offers excellent corrosion resistant, longevity and durability
  • Internal coating using food grade, epoxy coating for enhanced corrosion resistance design
  • Ease of service with backwash, rinse and regeneration systems.
  • High filtration performance and efficiency

 

Single System Specifications

Model Design
Flow Range
System Manifold Inlet/Outlet Media Sand Requirement Filtration
Area
IC31 2-4 m3/hr 1-inch 80kg 0.07m2
IC39 3-7 m3/hr 1 ½-inch 130kg 0.12 m2
IC50 5-12 m3/hr 1 ½-inch 250kg 0.20 m2
IC60 7-16 m3/hr 2-inch 380kg 0.28 m2
IC70 9-23 m3/hr 2-inch 500kg 0.38 m2
IC80 12-30 m3/hr 2-inch 680kg 0.50 m2
IC98 18-45 m3/hr 2/3-inch 1000kg 0.75 m2
IC110 20-60 m3/hr 3/4-inch 1350kg 0.95 m2
IC120 25-70 m3/hr 3/4-inch 1500kg 1.15 m2
IC135 35-85 m3/hr 3/4-inch 2000kg 1.45 m2
IC150 40-100 m3/hr 4/6-inch 2250kg 1.80 m2
IC190 65-170 m3/hr 4/6-inch 3800kg 2.84 m2
IC250 90-225 m3/hr 4/6-inch 6600kg 4.90 m2
IC300 160-400 m3/hr 6/8-inch 9500kg 7.07 m2

Multi-system Specifications

Model Design
Flow Range
System Manifold Inlet/Outlet Media Sand Requirement Filtration
Area
IC31-2 4-8 m3/hr 1 ½-inch 160kg 0.14 m2
IC39-2 6-14 m3/hr 1 ½-inch 260kg 0.24 m2
IC50-2 10-24 m3/hr 2-inch 500kg 0.40 m2
IC60-2 14-32 m3/hr 3-inch 760kg 0.56 m2
IC70-2 18-46 m3/hr 3-inch 1000kg 0.76 m2
IC80-2 24-60 m3/hr 3/4-inch 1360kg 1.00 m2
IC98-2 28-90 m3/hr 3/4-inch 2000kg 1.50 m2
IC110-2 38-100 m3/hr 4/6-inch 2700kg 1.90 m2
IC120-2 50-140 m3/hr 4/6-inch 3000kg 2.30 m2
IC135-2 70-170 m3/hr 6/8-inch 4000kg 2.90 m2
IC150-2 80-200 m3/hr 6/8/10-inch 4500kg 3.60 m2
IC190-2 130-340 m3/hr 8/10/12-inch 7600kg 5.68 m2
IC250-2 180-450 m3/hr 8/10/12-inch 9000kg 6.90 m2
IC300-2 320-800 m3/hr 10/12/14-inch 12000kg 9.20 m2

Note:

  1. Model numbers identify individual filter vessel size diameter (first set of number) and number of tanks per system (last set of number). End of model number “A” -automatic system, “M” -manual system; “SF” –single media filter; “DF”-dual media filter; “MMF” –multi medium filter; “CF”-activated carbon filter; “SSF” water softener filter. Filters may be specified either automatic or manual backwash control.
  2. Design flow range based on a Bacfree standard filtration range guideline of 24-61m3/hr/m2 (10-25USgpm/ft2). Models also available at higher flow rates. Selection of flow depends on the influent feed water quality, effluent filtered water requirements and applications, please consult factory.
  3. Recommended operating pressure range for best filtration performance is 20-80psi (1.5- 5.5 bar). please consult factory. Maximum operating temperature range 50°C. For higher operating pressure and operating temperature requirements, please consult factory.
  4. Single System and multi-system can be configured and custom made to accommodate specific spacing/footprint requirements.

System And Filter Media Specification

Multi-Medium Filter System (MMF) Filtration of suspended particles and contaminants to address the aesthetic water problems and impurities such as the taste, odour, and colour.
Designed for reducing suspended particulate down to 5 microns in size and achieve a turbidity of 3NTU or less.
Dual Media Filter System (DF) Design to addresses the water problems and impurities within closed loop water system and/or specific water problems such as iron and manganese within any open water system.
Single Media Filter System (SF) Addresses the water problems and impurities within closed loop water system and/or specific water problems such as iron and manganese within any open water system.
Carbon Filter System (CF) Addresses the chlorine, organic chemicals, odour and tastes water problems.
Softener Filter System (SSF) Addresses the water hardness cause by calcium and magnesium.

Note: i. Depending on the water problems and water requirements, a wide selection of filter medium are used - activated carbon, anthracite, birm, manganese greensand, manganese zeolite,  filox, zeolite , ion exchange resin etc.

Material Specifications

Filter Vessel 304 Stainless Steel (Standard)
316, 316L Stainless Steel (Custom Made)
System Vessel Pressure Maximum 10 Bar for IC31-IC120
Maximum 7 Bar for IC150-IC300
Exterior Surface Finishing Sandblasted Matt Finish (Standard)
Polished Finish
Manifolds and Piping Stainless Steel 304 (Standard)
316, 316L, ABS, PVC
Control Valve Manual
Chromed Brass Valves; Cast Iron Butterfly Valves
Stainless Steel Valves; CEL Stainless Steel Valves
Automatic
Pneumatic/ Electric Actuated Valves
Automatic Controller • Standard Automatic Valve Controller (SAVAC) 
• Advanced Automatic Valve Controller (AAVAC)

 

Copyright © 2010. All rights reserved. Bacfree Sdn Bhd.